Remote magnetic induction tachometers ТМи type (hereinafter – tachometers) are designed for continuous remote measurement of the rotation speed of machine and mechanism parts.
Tachometers consist of primary transducers Д-1М, Д-2М, Д-1ММ, Д-2ММ (hereinafter – primary transducer) and an indicating device of the ТМи type remote magnetic induction remote tachometer (hereinafter – indicating device).
Д-1М or Д-1ММ primary transducer operates with one indicating device, and the Д-2М or Д-2ММ primary transducer – with two.
Primary transducers and indicating devices of the same type are respectively interchangeable. Primary transducers and indicating devices can be supplied separately.
General specifications
Allowable basic error of the tachometer, %, maximum:
Climatic versions of primary transducers:
Climatic versions of indicating devices:
Communication line between the primary transducer and the indicating device is no longer than 50 m.
Weight, kg:
|
Magnetic induction tachometer version |
Measuring range, rpm |
Operating measuring range, rpm |
Tachometer factor |
|
|
lower range |
upper range |
|||
|
ТМи1-М1 |
250–2,500 |
750 |
2,500 |
1:1 |
Notes:
Ordering
When ordering, it is required to specify the following:
|
Item No. |
Name |
Kit number |
|||
|
1 |
2 |
3 |
4 |
||
|
Qty, pcs |
|||||
|
1 3 4 |
Indicating device |
1 |
2 |
1 |
2 |
Page 92 of the Catalog
Example for ordering the tachometer and its components
Magnetic induction tachometer ТМи2-М1 of climatic version У2, kit number 1:
ТМи2-М1 tachometer with an upper range limit of 2,000 rpm, climatic version У placement category 2, with installation kit 1:
“Tachometer ТМи2-М1 У2, kit 1 ТУ 25.02.111970-77”;
ТМи3М-М1 tachometer with an upper range limit of 3,000 rpm, climatic version T placement category 2, with installation kit 3:
“Tachometer ТМи3М-М1 Т2, kit 3 ТУ 25.02.111970-77”;
ТМи3М-М1 tachometer indicating device with an upper range limit of 3,000 rpm, climatic version T placement category 2, designed for export:
“Indicating device ТМи3М-М1 Т2 ТУ25.02.111970-77”;
Д-1М tachometer primary transducer operating with one indicating device with a 3-lug flange, climatic version У placement category 2, designed for export:
“Primary transducer Д-1М У2.Э ТУ25.02.111970-77”;
Д-2MM tachometer primary transducer operating with two indicating devices with a 4-lug flange, climatic version T placement category 2:
“Primary transducer Д-2ММ Т2 ТУ25.02.111970-77”.– page 92 of the Catalog
Overall and attachment dimensions