Designed
for measuring vacuum gauge and gauge pressure of air and nonaggressive gases.
General specifications
ТмМП-52-М3
kPa
|
НМП-52-М3
kPa
|
ТНМП-52-М3
kPa
|
Accuracy class
|
-0.16 to 0
|
0 to +0.16
|
-0.08 to +0.08
|
2.5
|
-0.25 to 0
|
0 to +0.25
|
-0.125 to +0.125
|
1.5; 2.5-1.5-2.5; 2.5
|
-0.4 to 0
|
0 to +0.4
|
-0.2 to +0.2
|
1.5; 2.5-1.5-2.5; 2.5
|
-0.6 to 0
|
0 to +0.6
|
-0.3 to +0.3
|
1.5; 2.5-1.5-2.5; 2.5
|
-1 to 0
|
0 to +1
|
-0.5 to +0.5
|
1.5; 2.5-1.5-2.5; 2.5
|
-1.6 to 0
|
0 to +1.6
|
-0.8 to +0.8
|
1.5; 2.5-1.5-2.5; 2.5
|
-2.5 to 0
|
0 to +2.5
|
-1.25 to +1.25
|
1.5; 2.5-1.5-2.5; 2.5
|
-4 to 0
|
0 to +4
|
-2 to +2
|
1.5; 2.5-1.5-2.5; 2.5
|
-6 to 0
|
0 to +6
|
-3 to +3
|
1.5; 2.5-1.5-2.5; 2.5
|
-10 to +0
|
0 to +10
|
-5 to +5
|
1.5; 2.5-1.5-2.5; 2.5
|
-16 to +0
|
0 to +16
|
-8 to +8
|
1.5; 2.5-1.5-2.5; 2.5
|
-25 to +0
|
0 to +25
|
-12.5 to +12.5
|
1.5; 2.5-1.5-2.5; 2.5
|
-40 to 0
|
0 to +40
|
-20 to +20
|
1.5; 2.5-1.5-2.5; 2.5
|
Note: Devices with accuracy class 1.5 are manufactured upon agreement with PJSC “SIW”.
Overall and attachment dimensions
Calibration interval is 2 years.
Climatic versions
- У3 – for operation at a temperature from minus 50 to plus 60°С and relative humidity up to 98% at 35°С.
- T3 – for operation at a temperature from minus 25 to plus 55°С and relative humidity up to 100% at 35°С.
Weight, 0.5 kg as maximum
Ordering
When ordering, it is required to specify the following:
1. Description
2. Designation
3. Indication range
4. Accuracy class
5. Climatic version designation
6. ТУ designation
Example of an order
Head gauge version У3 with an upper range limit of 10 kPa, accuracy class 2.5-1.5-2.5:
“Head gauge НМП-52-М3-10кПа-(2,5-1,5-2,5)-У3 ТУ 4212-160-00227471-2017”.
Head gauge version У3 with an upper range limit of 10 kPa, accuracy class 2.5, if supplied for export:
“Head gauge НМП-52-М3-10кПа-2,5-У3 Э ТУ 4212-160-00227471-2017”.