Pressure switches with integral pressure gauge ДЕМ-105М1-РАСКО (hereinafter – devices) are intended for signaling and relay control of the medium pressure by opening or closing electric contacts.
Scope of application:
- ventilation, air conditioning and cold supply systems;
- pump, compressor and turbine machine building;
- local automation systems at heat, water and power supply facilities.
Controlled medium is water, air, freons, oils and other liquids and gas, with a maximum viscosity of 0.8 Pa˙s, nonaggressive to the used structural materials.
Devices are fit for operation under conditions established for version ОМ5 as per GOST 15150, bur for operation within the temperature range from minus 20 to plus 60oC.
The devices are fitted with an electrical connector as per EN 175301-803 for coupling with external cable.
The devices are supplied with coupling thread М12х1.5, G1/4 and G1/2.
Guarantee period of storage is 18 months since the date of manufacture.
Guarantee service life is 12 months since the date of commissioning within the guarantee period of storage. – page 26 of the Catalog
GENERAL SPECIFICATIONS
1. Device designation, setpoint thresholds, basic error, actuation range and threshold return area value of devices are in compliance with those given in Table 1.
Table 1
Device designation
|
Setpoint thresholds*, MPa
|
Basic error, MPa, as maximum
|
Actuation range, MPa, as maximum
|
Return area uncontrollable, MPa,as maximum
|
ДЕМ-105М1-РАСКО-01
|
0.01 to 0.2
|
± 0.02
|
0.005
|
0.02
|
ДЕМ-105М1-РАСКО-02
|
0.02 to 1.0
|
± 0.05
|
0.01
|
0.05
|
* “Setpoint thresholds” – values of setpoints at which the requirements of technical conditions are satisfied for each device version.
|
Notes
1. Setting the device to a specific actuation setpoint shall be done by the manufacturer in compliance with the order.
2. The return area of devices is directed towards pressure decrease in relation to the setpoint.
3. The customer is allowed to reset a setpoint within the range of values specified in Table 1. – page 26 of the Catalog
2. Maximum allowable pressure of the controlled medium is given in Table 2.
Table 2
Designation
|
Maximum allowable pressure of the controlled medium*, MPa
|
ДЕМ-105М1-РАСКО-01
ДЕМ-105М1-РАСКО-02
|
1.5
|
____________
* Maximum exposure duration is 5 min
|
3. Devices are designed for operation at contact loads specified in Table 3.
Table 3
Current type
|
Voltage, V
|
Current, A
|
cos j, minimum
|
Frequency, Hz
|
min.
|
max.
|
DC
DC
|
30
|
0.1
|
1
|
-
|
-
|
AC
AC
|
250
|
1
|
10
|
0.6
|
50; 60
|
Page 27 of the Catalog
4. The devices are resistant to and preserve parameters under conditions of operating decreased temperature of minus 20°C and operating increased temperature of plus 60°C of ambient air.
5. As to dust or water ingress protection, devices are of version IP40.
6. Weight of the device is 1.3 kg as maximum.
Ordering information for ДЕМ-105М1-РАСКО devices:
1) ДЕМ-105М1-РАСКО device with setpoint thresholds from 0.02 to 1 MPa without indication of specific setpoint value with М-12х1.5 thread:
“Pressure switch ДЕМ-105М1-РАСКО-02 САФП.422319.001 ТУ”.
2) ДЕМ-105М1-РАСКО device with setpoint thresholds from 0.02 to 1 MPa and setpoint at 0.6 MPa with G1/4 thread:
“Pressure switch ДЕМ-105М1-РАСКО-02-0,6МПа-G1/4 САФП.422319.001 ТУ”. – page 27 of the Catalog
OVERALL AND MOUNTING DIMENSIONS
Figure 1 – Overall and mounting dimensions of ДЕМ-105М1-РАСКО pressure switches
ELECTRIC CIRCUIT DIAGRAM
Connector designation
|
Document designation
|
ХР1
|
XS1
|
Base as per EN 175301-803
|
Electric connector GDA4090S61 form А
|
EN 175301-803
(DIN43650)
|
Figure 2 – Electric circuit diagram of ДЕМ-105М1-РАСКО pressure switches